Not always. Tempe's IPC 403.2 says separate toilet facilities for each sex are not required in a structure or tenant space with a total occupant load of 30 or fewer, employees and customers combined. Single-user rooms and all-gender rooms with privacy also avoid the split. Section 410.2 drops drinking fountains at the same 30.
“Separate toilet facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 30 or fewer.”
- Applies to:
- Tenants, landlords, architects and plumbing contractors designing restrooms and drinking water in Tempe commercial spaces
- Official fee:
- none for the amendment itself; plan review and permit fees follow Appendix A, Table 1-A
- In force:
- 2024 International Plumbing Code with Tempe amendments, Tempe City Code 8-600 (last amended by Ord. O2026.24, 2026-06-04)
- Last verified:
- October 4, 2026, against the official page
Restroom count is where a tenant space gets expensive or cheap. In Tempe the line sits at 30 occupants, and it is not the same line a mile east in Mesa.
What does Tempe IPC 403.2 say?
Section 8-600 adopts the 2024 IPC and prints the section as amended. Section 403.2 starts with the rule: "Where plumbing fixtures are required, separate toilet facilities shall be provided for each sex." It then lists six exceptions:
- 1Dwelling units and sleeping units.
- 2Structures or tenant spaces with a total occupant load, including employees and customers, of 30 or fewer (the quote above).
- 3Mercantile occupancies where the maximum occupant load is 30 or fewer.
- 4Business occupancies where the maximum occupant load is 30 or fewer.
- 5Where single-user toilet rooms are provided in accordance with Section 403.1.2, the facilities need not be designated by sex.
- 6Where rooms with both water closets and lavatories are designed for use by all persons regardless of sex, and privacy is provided for water closets under 405.3.4 and for urinals under 405.3.5.
Two drinking water sections sit next to it. Section 410.2 says "Drinking fountains shall not be required for an occupant load of 30 or fewer." Section 410.4 says "Occupancies that provide food and/or beverage service to patrons do not need to provide drinking fountains." In other occupancies where fountains are required, "water dispensers, bottled water dispensers or bottled water, where free of charge," may replace not more than 50 percent of the required number.
What do the key terms mean?
- Occupant load. The text here counts employees and customers together. How the number is calculated comes from the building code, not from this section.
- Tenant space. One leased unit within a larger building. Exception 2 applies to a structure or a tenant space.
- Single-user toilet room. Exception 5 points to Section 403.1.2 for what qualifies; this page does not restate that section.
- Separate facilities. Distinct toilet rooms for each sex. The exceptions excuse the split, not the fixtures: the section opens with "Where plumbing fixtures are required."
Who does this cover?
Owners, tenants and designers of commercial and non-residential spaces in Tempe, including cafes, offices, shops and clinics.
It does not apply to dwelling units and sleeping units, which are exception 1. It also does not reduce the number of fixtures the code otherwise requires, and it does not replace accessibility rules, which this section does not address.
Quick check: small space or not?
| Situation | Separate by sex? | Why |
|---|---|---|
| Tenant space, total occupant load 28 | Not required | Exception 2 |
| Tenant space, total occupant load 31 | Required unless exception 5 or 6 applies | Above the 30 line |
| Retail space, maximum occupant load 30 | Not required | Exception 3 |
| Office suite with two single-user rooms | No sex designation required | Exception 5 |
| All-gender room with privacy for water closets and urinals | No separation required | Exception 6 |
| Restaurant, any size | Drinking fountains not needed | 410.4 |
| 20-person office | Drinking fountains not required | 410.2 |
| 45-person office needing fountains | Up to half may be water dispensers or free bottled water | 410.4 |
What does this look like in real life?
A 28-seat cafe. The total occupant load, staff and guests combined, comes in at 28. Exception 2 means the plans need not show separate rooms for each sex. The restroom still has to meet the fixture count and the accessibility rules.
The same cafe in Mesa. Mesa amends only Exception 2, to 25 or fewer, so Exception 2 no longer reaches a 28-person space there. Mesa's amendment text changes no other 403.2 exception, so the space still needs a different exception (for example a single-user room under Exception 5) to skip the split. A 28-person retail shop or office is a different case: Mesa's text does not touch the mercantile and business exceptions, so check whether one of them still applies before assuming Mesa requires separate rooms. That is the edge case that flips for the cafe: moving a concept from Tempe to Mesa, or copying a Tempe prototype plan across, can change the restroom layout.
A 45-person clinic. Exception 2 is out of reach. Single-user toilet rooms under Exception 5 avoid designating by sex, if they meet 403.1.2.
A brewery taproom. It provides beverage service to patrons, so 410.4 says it does not need drinking fountains.
What should you do next?
- 1Have the occupant load calculated for the specific tenant space before choosing a layout. The exceptions turn on the total, employees and customers combined.
- 2Decide whether a single-user room layout (Exception 5) gets you under or around the 30 line.
- 3Show the exception being claimed on the plan notes so the reviewer sees it. Plans go through Tempe's online permit portal under Section 8-105.3.
- 4For drinking water, note whether the use is food or beverage service (410.4), under 30 occupants (410.2), or needs fountains with a dispenser substitution.
- 5Keep ADA and accessibility design on a separate checklist; this section does not address it.
What do people get wrong?
- Using the Mesa number in Tempe, or the reverse. Tempe's Exception 2 says 30 or fewer. Mesa's amended Exception 2 says 25 or fewer, and Mesa leaves its other 403.2 exceptions as they are.
- Reading the exception as no restroom. The section opens with "Where plumbing fixtures are required."
- Counting only staff. Exception 2 counts "both employees and customers."
- Assuming every occupancy needs fountains. Section 410.4 exempts food and beverage service, and 410.2 exempts 30 or fewer.
The city's code text governs; this page explains it.
How Do Other Valley Cities Handle It?
| Where | What applies | Source |
|---|---|---|
| Mesa | Mesa amends only Exception 2, to 25 or fewer for a structure or tenant space, so Exception 2 no longer reaches a 28-person space there, while Tempe's does. Mesa's text leaves the other 403.2 exceptions unchanged, so a 28-person mercantile or business space may still qualify under one of those. Mesa also amends 410.2 so drinking fountains are not required for an occupant load of 50 or fewer. | Mesa City Code 4-5-2, IPC 403.2 and 410.2 as amended Verified October 4, 2026 |
| Buckeye | Buckeye amends IPC 410.2 by changing the number 15 to 50, so its small-occupancy drinking fountain exemption reaches 50. | Buckeye City Code 15-2-4(B), IPC 410.2 Verified October 4, 2026 |
| Chandler | Chandler amends 410.4 so that in occupancies where drinking fountains are required, water dispensers connected to the potable water system may be substituted for the first required fountain, and any water dispenser for not more than 50 percent of the required number. | Chandler City Code 29-4.3 (amends IPC 410.4) Verified October 4, 2026 |
This page explains the rule. The official text at the source above governs.
Commercial Plumbing in Other Cities
- ChandlerChandler amendment to IPC 1003.3.7: how big must a grease interceptor be?
- MesaDoes a small Mesa business need separate men's and women's restrooms? IPC 403.2 and 410.2
- PhoenixCan a Phoenix business dilute corrosive waste instead of neutralizing it?
- ScottsdaleWhen does Scottsdale require a grease interceptor?
- AvondaleAvondale City Code 24-104 and 24-105: grease interceptors, pretreatment plans and the discharge survey
- BuckeyeBuckeye City Code 16-10-2: grease interceptor size, upkeep and records for restaurants
More Tempe Codes and Permits
- Commercial PlumbingWhat can a Tempe business not put down the sewer? City Code 27-10
- Commercial PlumbingTempe City Code 27-22: grease traps, interceptors and the garbage disposal ban
- Commercial PlumbingDoes a Tempe business need a wastewater discharge permit? City Code 27-32
- Commercial PlumbingCan a Tempe business open with a temporary certificate of occupancy? City Code 8-111
- Commercial PlumbingDoes a Tempe tenant improvement need a plumbing permit? City Code 8-105
- Commercial PlumbingTempe FOG inspections: pumping schedule, records and what inspectors check
Related Rules and Questions
- ChandlerChandler drinking fountain rules: when a water dispenser can replace one
- TempeTempe IPC 608.7.2: which facilities need a secondary backflow assembly?
- FAQDo single-user restrooms satisfy code in a small space?
- FAQWhat are the ADA plumbing requirements for a commercial restroom?
- FAQDoes code require a drinking fountain or bottle filler?
- Commercial Plumbing