Chandler drinking fountain rules: when a water dispenser can replace one

Verified September 29, 2026
In Short

Yes, in most occupancies. Chandler City Code 29-4.3 lets a water dispenser connected to the potable water system stand in for the first required drinking fountain, and a dispenser can replace not more than 50 percent of the required fountains. It does not change the accessible-fountain rules under the ADA.

Official Source
Chandler City Code 29-4: International Plumbing Code adoption and amendments (Municode)
Chandler City Code 29-4.3 (amends 2024 IPC 410.4, Substitutions)
“water dispensers connected to the potable water system shall be permitted to be substituted for the first required fountain”
Applies to:
Designers, tenants, owners and plumbing contractors on Chandler projects that must provide drinking fountains
In force:
2024 IPC 410.4 as amended by Chandler City Code 29-4.3 (Ord. 5108, adopted 2024-12-09, effective 2025-07-01), since July 1, 2025
Last verified:
September 29, 2026, against the official page

Chandler wrote a drinking fountain substitution rule into its local plumbing amendments. A tenant that needs one fountain can put in a plumbed dispenser instead, and larger buildings can swap part of the count. The catch is that the swap has limits, and the ADA has its own say on fountains that stay.

What does Chandler City Code 29-4.3 say?

The rule is a single sentence added to the plumbing code. Chandler's section 29-4.3 amends the IPC "Substitutions" section by deleting its second sentence and replacing it with this text: "In all other occupancies where drinking fountains are required, water dispensers connected to the potable water system shall be permitted to be substituted for the first required fountain and any water dispenser shall be permitted to be substituted for not more than 50 percent of the required number of drinking fountains." That is the whole amendment.

Here is what that sentence does, part by part:

  • It only replaces the second sentence. The first sentence of IPC 410.4 stays as the international code wrote it. The new wording starts "In all other occupancies," because, in the 2024 International Plumbing Code (ICC) Section 410.4 Substitution, the first sentence covers restaurants: "Where restaurants provide drinking water in a container free of charge, drinking fountains shall not be required in those restaurants."
  • The first fountain. A water dispenser connected to the potable water system can be the first required fountain.
  • The cap. Dispensers can replace no more than half of the required fountains.

The section is part of Chandler's adoption of the 2024 International Plumbing Code. The ordinance history for 29-4 ends with Ord. No. 5108, 12-9-24, eff. 7-1-25.

What do the key terms mean?

  • Water dispenser: the code text does not define it here. In practice it is a bottle-filling station or plumbed water cooler (a reading, not a code definition).
  • Connected to the potable water system (the code's wording): plumbed to the building's drinking water supply. A cooler fed by a jug and not plumbed does not fit the first-fountain wording (a reading).
  • Required fountains: the number the IPC fixture table produces for your occupancy and occupant load, before any substitution.
  • Substitution: a dispenser counted in place of a fountain toward the required number.

Who does this cover?

It covers projects in Chandler where the plumbing code requires drinking fountains. In practice that means commercial and institutional buildings, including tenant improvements (a reading).

It does not apply if the occupancy is one the unchanged first sentence of 410.4 addresses, or if the project is outside Chandler. Chandler's 29-4 lists no amendment to 410.2, so the model code's small-occupancy threshold is not changed there. That is different from Phoenix.

Quick check: can a dispenser replace your fountain?

SituationCan a dispenser count?Why
One fountain required, plumbed dispenser proposedYes, if it is connected to the potable water system29-4.3, first clause
One fountain required, bottle-jug cooler proposedNo, under the wordingNot "connected to the potable water system"
Four fountains requiredUp to two dispensersThe 50 percent cap in 29-4.3
Three fountains requiredOne dispenser, by a cautious reading50 percent of three is 1.5, and the cap is a maximum
A fountain is provided and you want a bottle filler to be the accessible unitNoThe Access Board says a bottle filler cannot substitute for the wheelchair or standing-height fountain
A small tenant space with a low occupant loadAsk the plan reviewer whether fountains are required at all29-4 does not change 410.2

What does this look like in real life?

A small office suite. A tenant improvement needs one drinking fountain on the count. The designer specifies a plumbed bottle-filling station in the break room instead. Under 29-4.3 it can be the first required fountain, so the plan shows a dispenser and no fountain.

A school wing with four required fountains. The designer wants dispensers everywhere because students carry bottles. The code allows dispensers for not more than 50 percent, so at most two of the four can be dispensers. The other two stay fountains, and the ADA split applies to them.

The flip: a bottle filler as the accessible unit. A building keeps two fountains, one for wheelchair users and one for standing users, and the designer proposes a bottle filler to replace the low one. The Access Board says a water cooler, bottle filler or nearby sink cannot substitute for either type of fountain, so the ADA side does not let it take the place of either fountain.

What should you do next?

  1. 1Get the occupant load from the building plans and find the required fountain count in the IPC fixture table for your occupancy.
  2. 2Decide how many fountains you want to substitute: one for the first fountain, or up to 50 percent of the required number.
  3. 3Show every dispenser as plumbed to the potable water system on the plumbing plans.
  4. 4Keep the ADA-required accessible fountain units as real fountains.
  5. 5For a question about whether your occupancy is covered, call Chandler Development Services at 480-782-3000 (215 E. Buffalo St.). The city's permit manual also lists the Plan Reviewer of the Day at 480-782-3078 or prod@chandleraz.gov.

What do people get wrong?

  • Myth: a dispenser replaces any fountain. The code sets a 50 percent limit for dispensers, and the ADA rules for provided fountains still apply.
  • Myth: any water cooler counts. The first-fountain wording requires a dispenser connected to the potable water system.
  • Myth: Chandler changed the small-occupancy rule like Phoenix did. Chandler's 29-4.3 covers substitution only. Phoenix and Buckeye amended 410.2, the section that sets the small-occupancy exemption.
  • Myth: the bottle filler saves the accessible fountain. The Access Board is direct that it cannot.

This page describes Chandler's published amendment. The plan reviewer decides how it applies to a specific occupancy, so confirm before you finalize the fixture schedule.

How Do Other Valley Cities Handle It?

WhereWhat appliesSource
PhoenixPhoenix amends IPC 410.2 so drinking fountains are not required for small occupancies, with the occupant-load threshold set at 50 or fewer.Phoenix Amendment to 2024 IPC, Section 410.2 (Ord. G-7397, effective 2025-08-01)
Verified September 29, 2026
BuckeyeBuckeye amends IPC 410.2 with one instruction, Change "15" to 50, raising the small-occupancy fountain threshold.Buckeye City Code 15-2-4(B), Section 410 Drinking Fountains
Verified September 29, 2026
MesaMesa's plumbing plan checklist lists an exception to providing drinking fountains for occupant loads of 50 or less.Mesa Plumbing Plan Submittal Checklist, item 8 (M-IPC 410.2)
Verified September 29, 2026

This page explains the rule. The official text at the source above governs.