Shell building backflow, oil separators for garage bays, tempered water for eyewash stations and the wastewater paperwork cities ask industrial tenants for.
Valley warehouses and industrial buildings are judged on the water service, the floor drains and what goes into the sewer. Phoenix and Mesa require an RP backflow assembly when one service feeds several tenants. Repair bays with floor or trench drains need oil separators, and eyewash stations fed hot and cold water need a tempering valve.
The rules that apply
Each rule links to the official text we read it from. Cities change these, so check the source before a big decision. Last checked 2026-09-29.
One service, several tenants
PhoenixRetail and industrial shell buildings where one water service supplies more than one tenant need a reduced pressure (RP) assembly. Assemblies are tested at least once a year and records kept three years.
Source: Phoenix City Code 37-144Shell and multi-tenant buildings
MesaShell buildings, and commercial or industrial buildings where one service connection supplies multiple tenants, need a reduced pressure principle backflow prevention assembly (RPA).
Source: Mesa City Code 8-1-8Oil separators at garage bays
Model code (2024 IPC)Repair garages with floor or trench drains, and factories that produce oily or flammable liquid wastes, need an oil separator before those wastes reach the building drain. Storage-only garage areas don't.
Source: 2024 IPC 1003.4Vehicle and equipment service floors
GilbertVehicle and equipment service facilities may have floor drains only when they connect to a pretreatment system, and parts-cleaning sinks and tanks may not connect to the sewer.
Source: Gilbert Town Code 66-245Eyewash and emergency showers
Model code (2024 IPC)Emergency showers and eyewash stations conform to ISEA Z358.1. Where hot and cold water are supplied, only an ASSE 1071 temperature-actuated mixing valve may control the temperature. No waste connection is required.
Source: 2024 IPC Section 411Interceptor pumping
PhoenixGravity interceptors are pumped before solids and oil reach 25 percent of liquid volume and at least every 12 months unless the city grants a variance. Records stay on site three years.
Source: Phoenix City Code 28-15Industrial plan review and permits
PhoenixDrawings for industrial manufacturing or servicing facilities go to the Industrial Pretreatment Program before the Planning and Development Department. Class A permits cover categorical processes and users averaging 25,000 gallons per day of process wastewater.
Source: Phoenix Wastewater Discharge PermittingWastewater questionnaire
Gilbert, ChandlerEvery nonresidential user files a wastewater discharge questionnaire. Gilbert requires it yearly with the business license; Chandler requires it before any discharge to the sewer.
Source: Gilbert Town Code 66-177The water service: one meter, many tenants
The first question on a multi-tenant warehouse is how many water services feed it. Phoenix City Code 37-144 requires a reduced pressure (RP) assembly on retail and industrial shell buildings when one service supplies more than one tenant. Mesa goes a step further and names shell buildings outright, along with any commercial or industrial building where one service connection feeds multiple tenants.
The logic is simple. The landlord can't see what a new tenant bolts onto the water line, whether that's a chemical dispenser, a pressure washer or a process tank, so the city protects the main at the property line. Every Phoenix assembly is tested at least once a year by a certified tester, results go to the city, and the records stay for three years. A failed test means repair or replacement and a retest, and a repair has to be done by a certified repairer following ASSE Standard 5130.
Tenants with their own hazards may need more protection inside the suite. Phoenix lists a long run of industrial uses on their own, from chemical and plating plants to metal fabrication. Here's RPZ vs double check and the full Phoenix Chapter 37 rules.
Garage bays, trench drains and oil separators
A floor drain in a truck bay is a sewer connection for whatever leaks off a vehicle. The 2024 International Plumbing Code, one of the two plumbing codes Phoenix lets designers use (the UPC is the other), requires an oil separator at repair garages with floor or trench drains and at factories producing oily or flammable liquid wastes. Areas used only for parking or storage don't need one. Separators can be listed and labeled, or designed to the code. A designed separator where vehicles are serviced or washed holds at least 6 cubic feet for the first 100 square feet drained, plus 1 cubic foot per additional 100 square feet.
Phoenix City Code 28-12 lets the city require interceptors at any facility handling oily, flammable or solid-laden wastes, and 28-15 sets the pumping rule: before contents reach 25 percent of the liquid volume, and at least every 12 months. Gilbert is stricter on the floor itself. Vehicle and equipment service facilities can have floor drains only when they tie into a pretreatment system, and parts washers can't connect to the sewer at all.
One more IPC detail: Section 1003.2 says wastes that don't need separation shall not go into a separator. Restroom lines stay out of the oil separator. See the Phoenix interceptor rule for who needs one.
Eyewash stations and tempered water
Section 411 of the 2024 IPC covers emergency showers and eyewash stations. They must conform to ISEA Z358.1. Where both hot and cold water feed a station, only an ASSE 1071 temperature-actuated mixing valve may control the temperature, and a water heater feeding a station directly must comply with ASSE 1085. The code doesn't require a waste connection, though a floor drain nearby often makes testing less messy.
Which areas need a station is a workplace safety question for your safety officer. Getting tempered water to it is plumbing. That's the part we do.
Industrial wastewater: when the city gets involved
Most warehouses discharge restroom and break-room waste and never hear from a pretreatment program. Manufacturing is different. Phoenix wants construction drawings for industrial manufacturing or industrial servicing facilities reviewed by its Industrial Pretreatment Program before they go to the Planning and Development Department. Class A permits go to federally regulated categorical processes, users averaging 25,000 gallons per day of process wastewater, and effluent that could affect the treatment plants. Read the Phoenix industrial wastewater permit before a new tenant moves in.
East Valley cities ask everyone. Gilbert requires every nonresidential user to file a wastewater discharge questionnaire each year with the business license. Chandler requires one from all non-residential users before they discharge, and bases the type of Industrial User Permit on the activities at the site. Chandler also lets its building official issue an annual permit for alterations to a previously approved premise instead of a permit for each one; see Chandler's annual facility permit.
How HQ works with warehouses and industrial buildings
We jet floor and trench drains with hydro jetting, camera and repair sewer lines, service oil separators and interceptor piping, install water heaters and tempered water lines, run gas lines, and replace backflow assemblies. Planning a tenant change? We can map shutoffs and set up a planned commercial water shutoff. We're available 24/7, and estimates are free.
Services and tools
Codes and permits
- Phoenix Chapter 37 cross-connection control
- Phoenix industrial wastewater permit
- Phoenix City Code 28-12: when interceptors are required
- Chandler annual facility permit
- Phoenix annual permit for plumbing alterations
- Phoenix commercial tenant improvement permit
- Phoenix 2024 building construction code adoption
Questions we've answered
- Commercial plumbing repairs: tenant or landlord responsibility?
- What plumbing is involved in a commercial tenant improvement (TI)?
- How do I plan a water shutoff for my commercial building?
- How often does a commercial backflow preventer need testing in Arizona?
- RPZ vs double-check backflow assembly: what's the difference?
- Where is my backflow preventer and what does it look like?
- Why is my floor drain backing up?
- Why does my commercial building smell like sewer gas?
- Why isn't my commercial water heater making enough hot water?
- What are the ADA plumbing requirements for a commercial restroom?
- What should a commercial plumbing preventive maintenance plan include?
- What plumbing work needs a permit in Phoenix?
Sources
- Phoenix City Code 37-143 and 37-144, backflow prevention
- Phoenix City Code 28-12, interceptors required
- Phoenix City Code 28-15, interceptor maintenance
- City of Phoenix, Wastewater Discharge Permitting Information
- Phoenix 2024 IPC amendments (1003.2)
- Phoenix Construction Code History (TRT 00550)
- 2024 International Plumbing Code, Chapter 4 (Section 411)
- 2024 International Plumbing Code, Chapter 10 (Sections 1003.2, 1003.4, 1003.4.2.2)
- Mesa City Code 8-1-8, customers requiring a backflow assembly
- Gilbert Town Code 66-245, vehicle and equipment service facilities
- Gilbert Town Code 66-177, wastewater discharge questionnaire
- Chandler City Code 29-2.8, annual permit
- Chandler Industrial Pretreatment Program, Industrial User Permits
Other industries we serve
Grease interceptor rules by city, pumping schedules, health code plumbing and soda backflow, plus 24/7 kitchen drain service.
Arizona landlord plumbing duties, kitchen stack clogs, water heaters, planned shutoffs, backflow testing and sewer laterals.
Shared grease interceptors, strip center backflow, tenant improvement permits, vacant suite odors and the records cities ask for.
County hotel plumbing rules, pool and spa backflow, laundry lint interceptors and hot water for the morning rush, plus 24/7 repair.
Brewery backflow, sewer pH and temperature limits, carbonator RPs, bar floor sinks, glass washers and trench drain jetting.
EPA amalgam separator rules, Phoenix compliance reports, clinic backflow, sterilizer and vacuum plumbing, and tenant improvement permits.
Lab backflow, lead testing at fountains, cafeteria grease interceptors, worn restrooms and summer break maintenance for Valley campuses.
Dry traps, fellowship hall kitchen grease, restroom loads on event days and irrigation backflow for Valley houses of worship.
Locker room showers, hair-clogged drains, sewer smells from dry traps and pool and spa plumbing rules for Valley gyms.
State board hot water and drain rules, shampoo bowl clogs, hair interceptors, chemical dispenser backflow and salon water heaters.
Lint interceptor rules, city cleaning records, laundry backflow, water heaters sized for peak demand and sewer line care.
Sand and oil interceptor rules, 12-month pumping, three-year records, RP backflow and bay and reclaim line jetting.
Condo vs owner plumbing duties, shared sewer lines, irrigation backflow testing, community pools and emergency water shutoffs.
Plumbing Help for Warehouses and Industrial
Talk to a real dispatcher who knows commercial work. Upfront pricing before work starts, 24/7 for emergencies.