Gilbert requires the entire contents of a grease removal device to be pumped out at least every six months, and more often when needed to keep grease out of the sewer. The director can accept a longer interval if the owner shows it works. Emulsifiers are banned, and additives can never be the only maintenance.
“At a minimum, the entire contents shall be removed every six months, or more frequently as needed to prevent carry over of grease into the POTW”
- Applies to:
- Owners, operators and managers of Gilbert restaurants and other food service facilities with a grease removal device, and the haulers who service them
- Official fee:
- not applicable
- In force:
- Gilbert Town Code Ch. 66, Art. VI, Div. 3 (Ord. 1612, 12-14-04, Municode Supp. 103)
- Last verified:
- September 29, 2026, against the official page
Most Valley cities tell a restaurant to pump "as needed" and leave the number to a rulebook. Gilbert puts a number in the code: six months. It also says what does not count as maintenance, which is where enzyme sales pitches run into trouble.
What does Gilbert Town Code 66-244(d) and (e) say?
Pumping. Subsection (d) says the contents of all grease removal devices "shall be removed periodically as necessary to prevent violations of this chapter." Then it sets the floor: "At a minimum, the entire contents shall be removed every six months, or more frequently as needed to prevent carry over of grease into the POTW." The one way out is that the director can accept a longer interval if you demonstrate it works to the director's satisfaction.
Additives. Subsection (e) covers biological or chemical additives. If you use one, you remain responsible for keeping the device effective, and you must notify the director and provide the safety data sheets. Using additives alone "is not considered an acceptable maintenance practice", and they cannot be the sole method of treating or maintaining the discharge. Emulsifiers are prohibited in grease removal devices, and using them to cut how often you pump is expressly prohibited.
Records and access. Section 66-243(d) says pretreatment devices must be kept in continuously efficient operation at the owner or operator's expense. Written records of cleaning, repair, calibration and maintenance stay at the facility for at least three years and go to the director on request. The device must be easy to reach for cleaning and inspection.
What do the key terms mean?
- Entire contents: the whole volume in the device, not a skim of the grease cap. Our reading is that a partial pump-out does not meet the six-month minimum.
- POTW: the publicly owned treatment works, the town's sewer collection and treatment system.
- Emulsifier: a product that breaks grease into small droplets so it flows out with the water. Gilbert bans it in grease devices.
- Additive: a biological or chemical product added to help the device work. Allowed as a supplement, with notice and data sheets.
Who does this cover?
Every owner or operator with a grease removal device in Gilbert. That includes restaurants, schools, grocery and convenience stores and the other food service facilities the town lists. Haulers do the work, but the code puts the duty and the paperwork on you.
Quick check: is this device on schedule?
| Question | Answer that passes | Where it comes from |
|---|---|---|
| Last full pump-out | Within six months | 66-244(d) |
| Pumped only when full or smelly | Not enough on its own | 66-244(d) says every six months at minimum |
| Interval longer than six months | Only with the director's acceptance | 66-244(d) |
| Using enzymes or bacteria | Allowed as a supplement, with notice and data sheets | 66-244(e) |
| Using an emulsifier | Prohibited | 66-244(e)(2) |
| Records | On site for three years | 66-243(d) |
What does this look like in real life?
A busy grill on a six-month contract. The hauler pumps in March and September and leaves a manifest each time. The manager files it in one binder. That meets the minimum, but if the line runs slow in July, "more frequently as needed" means an extra pump-out.
A bakery with a light fryer load. The owner wants to skip a service. The code allows a longer interval only if the owner demonstrates it works to the director's satisfaction. The safe move is to ask first and get the answer in writing.
The edge case: the enzyme dosing system. A vendor installs a dosing unit and says pumping can drop to once a year. Under (e) additives cannot be the sole method, and an emulsifier cannot be used to reduce service frequency. If the product is not an emulsifier, you still notify the director and file the data sheets, and the six-month floor still applies unless the director agrees otherwise.
What should you do next?
- 1Check the date of the last full pump-out on your hauler's manifest.
- 2Put the next one on the calendar, six months out at the latest.
- 3Start a binder for manifests, cleaning notes and repair records. Keep three years.
- 4If you use any additive, send written notice and the safety data sheets to the Town of Gilbert at (480) 503-6000 (ask for the pretreatment program), and confirm the product is not an emulsifier.
- 5If you want a longer interval, ask the director in writing through the same pretreatment contact and show your records.
What do people get wrong?
- "Pump when it smells." The code sets a six-month minimum and says more often when needed. Odor is a late signal.
- "Enzymes replace pumping." Additives cannot be the only maintenance, and emulsifiers are banned.
- "Every Valley city pumps on the same schedule." Tempe counts 30 or 90 days and Glendale 180 days. Gilbert's floor is six months.
- "The hauler keeps my records." The code puts record-keeping on the owner or operator, at the facility.
How Do Other Valley Cities Handle It?
| Where | What applies | Source |
|---|---|---|
| Tempe | The city page says traps and interceptors are serviced every 30 or 90 days by size, and records are kept on site. | Tempe FOG Program page Verified September 29, 2026 |
| Glendale | Pumped or cleaned out completely at least every 180 days. No decanting waste back into the trap or interceptor, and records stay at the facility for three years. | Glendale City Code 33-238 Verified September 29, 2026 |
This page explains the rule. The official text at the source above governs.
Commercial Plumbing in Other Cities
- GlendaleGlendale City Code 33-238: grease interceptors must be pumped every 180 days
- MesaWhat can a Mesa business not put down the drain? City Code 8-4-15 prohibited discharges and limits
- MesaKeeping Mesa pretreatment equipment running: City Code 8-4-21 records and bypass rules
- MesaMesa City Code 8-4-22: who needs a grease interceptor and what upkeep it takes
- MesaCan you cut a newly paved Mesa street for a sewer or water repair? City Code 9-1-6
- MesaHow big must a Mesa restaurant grease interceptor be? City Code 8-4-22(E)
More Gilbert Codes and Permits
- Commercial PlumbingGilbert Town Code 66-244: grease removal devices for restaurants and food service
- Commercial PlumbingGilbert Town Code 66-245: floor drains and wash racks at auto shops and car washes
- Backflow PreventionGilbert Town Code 10-92(c): which backflow assembly does your kind of property need?
- Permits and InspectionsGilbert Town Code 66-8: the permit to dig a street or alley for a water or sewer connection
Related Rules and Questions
- Valley-WideGrease Trap and Interceptor Rules by Valley City
- PhoenixPhoenix City Code 28-12: Which businesses must install a grease or oil interceptor?
- ChandlerChandler amendment to IPC 1003.3.7: how big must a grease interceptor be?
- ChandlerDoes a Chandler restaurant need a grease trap or interceptor?
- FAQHow often should a restaurant grease trap be pumped?
- FAQAre enzyme or grease-dissolving drain treatments allowed for Phoenix restaurants?
- FAQWhat is FOG (fats, oils, and grease) in plumbing?
- Commercial Drain Cleaning