Under Surprise Municipal Code 58-259, initial and requested backflow test reports go to the city within 48 hours of the test, and annual recertification reports within ten working days of the renewal date. The tester must be ADEQ-recognized and on the city's approved list, and the city will not accept a failed report as complete.
“A copy initial and requested testing reports must be submitted to the city within 48 hours of the testing procedure.”
- Applies to:
- Owners and managers of properties with backflow devices on the Surprise water system, and the certified testers who test them
- Official fee:
- not published
- In force:
- Surprise Municipal Code Ch. 58, Art. IV, Div. 5 (Ord. 2012-06, 2012)
- Last verified:
- October 4, 2026, against the official page
Most backflow trouble in Surprise is paperwork, not hardware. The assembly passes, the tester packs up, and the report never lands where the city expects it. The code section sets two different deadlines, and the city's own tester page adds a third rule about how the report must travel.
What does Surprise Municipal Code 58-259 say?
Subsection (b) is the deadline: "A copy initial and requested testing reports must be submitted to the city within 48 hours of the testing procedure." The next sentence covers the yearly one: "Test reports for the annual recertification must be submitted within ten working days of the required renewal date."
The remaining subsections set the rules around the report:
- (a), who is responsible: the property owner where devices are installed has to have "inspection, tests, maintenance and repairs made in accordance with these regulations."
- (c), the form: reports go on a city approved form and must list the test date, tester's name, the tester's certification number and the results. "The city will not accept a failed testing report as a completed testing report."
- (d) and (e), the tester: someone certified by an organization recognized by the Arizona Department of Environmental Quality, who is on the city's approved testers list "at the time the test is performed."
- (f) and (g), repairs: a defective device "shall be repaired or replaced at the owner's expense without delay," and a device "shall not be bypassed at any time."
What do the key terms mean?
- Initial test: the first test after a device is installed. The city's owner page also calls for a test before a device goes into service, after a repair, or after the meter is installed.
- Requested test: a test the city asks for. Section 58-255 says devices are tested "upon installation, annually or as requested by the city."
- Annual recertification: the yearly test. The code does not define the renewal date. Ask the city which date it has on file for your device.
- Working days: the code does not define it. The usual reading is business days, which is a reading, not a definition.
Who does this cover?
The property owner is the responsible party under (a). The tester has duties too: the city's tester page lists what a tester needs to be on the approved list and says reports must go through the SAMS Universal Tester website, where "The City no longer accepts reports by email or mail in."
Quick check: which clock applies?
| Event | Deadline | Where it comes from |
|---|---|---|
| First test after installation | Report to the city within 48 hours of the test | 58-259(b) |
| Test the city requests | Report within 48 hours of the test | 58-259(b) |
| Annual recertification | Report within ten working days of the required renewal date | 58-259(b) and the city tester page |
| City sets a new meter | Test within 48 hours, with the report to Environmental within 48 hours | City owner page |
| Test result is a fail | Not accepted as a completed report; repair or replace "without delay" | 58-259(c) and (f) |
| Device replaced | New certification, with old and new device details on the form | City owner page |
What does this look like in real life?
A routine annual test. The tester runs the test with a calibrated gauge, files the report through SAMS, and the owner keeps a copy. The city's owner page says copies go to the device owner, the water provider and the tester.
A failed test on a Friday. The first report shows a failure. Under (c) it does not count as complete. Under (f) the owner repairs or replaces the device at their own expense without delay, so the report that satisfies the city is a passing one.
The edge case: a new building. The city sets the meter, and the device is tested within 48 hours. With only 48 hours, book the tester before the meter is set, not after.
What should you do next?
- 1Pull your last test report and note the renewal date, the tester's certification number and the device serial number.
- 2Pick a tester from the Recognized Certified Backflow Testers list on the city's tester page.
- 3Ask the tester to submit through SAMS Universal Tester, since the city no longer accepts email or mail reports.
- 4For a replaced device, make sure the form includes the manufacturer, model, serial number, size and type of the new device, and the old device's information in the comments.
- 5Keep the report with your building records. The city's owner page lists test reports, repairs and replacements as the records the owner's contact person keeps.
- 6Questions go to backflow@surpriseaz.gov. The tester page lists 623-222-7030 for tester support.
What do people get wrong?
- Assuming the tester files the report and the owner is done. The code puts responsibility on the property owner.
- Treating a failed report as a late-but-filed report. The city will not accept it as complete.
- Using an unlisted tester because the certification is valid. The tester must also be on the city's list at the time of the test.
- Mixing up the two deadlines. 48 hours is for initial and requested tests, and ten working days is for annual recertification.
- Using a potable test kit on a reclaimed assembly. The tester page says the potable kit is not to be used on reclaimed water backflow assemblies.
Full text and source
The rule is Surprise Municipal Code Sec. 58-259 on Municode, with the city's two backflow pages beside it. HQ tests and repairs domestic backflow assemblies. This page is an explanation, and the code and the city's pages govern.
How Do Other Valley Cities Handle It?
| Where | What applies | Source |
|---|---|---|
| Mesa | Mesa wants each test record within seven calendar days of the test or by the compliance due date, whichever is sooner, and a retest within 24 hours after any overhaul, repair or replacement. | Mesa City Code 8-1-11(I) and (J) Verified October 4, 2026 |
| Glendale | Glendale has no fixed day count. A copy of each record must be promptly submitted to the city after the activity it records. | Glendale City Code 33-94(d) Verified October 4, 2026 |
| Tempe | Tempe has the user notify the department 15 days before each annual test so a city representative can witness it, and the test results go to Community Development before the certificate of occupancy. | Tempe City Code 33-107(c) and (d) Verified October 4, 2026 |
This page explains the rule. The official text at the source above governs.
- Municode: Surprise Municipal Code Sec. 58-259, Records
- Municode: Surprise Municipal Code Sec. 58-255, Contamination
- City page: Surprise Water Resource Management, Backflow Assembly Testers
- City page: Surprise Water Resource Management, Backflow Prevention Owner Information
- Mesa Municode: City Code 8-1-11, Assembly testing, maintenance, repair and records
- Glendale Municode: City Code Sec. 33-94, Test; maintenance; records
- Tempe Municode: City Code Sec. 33-107, Maintenance, testing and records
Backflow Prevention in Other Cities
- AvondaleAvondale City Code 24-10: annual backflow test, 7-day records and the 20-day shutoff clock
- AvondaleAvondale City Code 24-6 and 24-7: which backflow assembly you need and where it goes
- BuckeyeBuckeye City Code 17-4-3: backflow assemblies, yearly tests, 10-day repairs and shutoff
- ChandlerHow long do you have to install a backflow device after a Chandler notice?
- ChandlerWhich backflow device does a Chandler business need?
- ChandlerChandler City Code 52-36: backflow assemblies on commercial building plans
More Surprise Codes and Permits
- Backflow PreventionDoes every Surprise commercial connection need a backflow device?
- Sewer LinesSurprise City Code 58-312(b): permits to repair a commercial sewer lateral
- Sewer LinesSurprise City Code 58-315: where a private sewer ends and the city's begins
- Commercial PlumbingDo you need an industrial waste discharge permit in Surprise?
- Sewer LinesSurprise City Code 58-425 and 58-218: permits to dig for sewer and water lines
- Water Supply and PipesHow much does the City of Surprise charge to install a water meter?
Related Rules and Questions
- MesaMesa City Code 8-1-11: annual backflow testing, repair deadlines and who can test
- MesaWho can test backflow assemblies in Mesa? City Code 8-1-12 recognized testers
- GlendaleGlendale City Code 33-94: annual backflow test, records and shutoff
- Queen CreekQueen Creek backflow testing: annual reports go through BSI Online, with a $14.95 filing fee
- ArizonaArizona Administrative Code R18-4-215: Backflow Prevention and Annual Testing
- FAQMy backflow assembly failed its test. What happens next?
- FAQHow do I hire a backflow tester and what's on the report?
- FAQWho is allowed to test backflow assemblies in Arizona?
- Commercial Plumbing