Who can test backflow assemblies in Mesa? City Code 8-1-12 recognized testers

Verified September 29, 2026
In Short

Only a tester the city recognizes may test or maintain a backflow assembly in Mesa. To be recognized, a tester submits an application, signs the city's tester agreement, proves certification and files a current gauge accuracy report. Equipment must be calibrated every year, and late test records or improper protocol can lead to discipline.

Official Source
Mesa City Code, Title 8, Chapter 1, Section 8-1-12: Recognized Backflow Prevention Assembly Testers (Municode)
Mesa City Code 8-1-12, Recognized Backflow Prevention Assembly Testers
“Any person performing backflow maintenance and testing within the City must be a recognized backflow prevention assembly tester and meet all requirements of this Section.”
Applies to:
Building owners and managers who hire a backflow tester in Mesa, and the testers who work there
In force:
Mesa City Code Title 8, Chapter 1 (Ord. 5909, 12-9-24)
Last verified:
September 29, 2026, against the official page

A backflow test only counts in Mesa if the person who ran it is on the city's list. Owners who hire whoever is cheapest can end up with a test report the city will not accept, and then a repair deadline running on an assembly they thought was current.

What does Mesa City Code 8-1-12 say?

Subsection (A) says that any person performing backflow maintenance and testing within the city must be a recognized backflow prevention assembly tester and meet all requirements of the section. The Department approves an applicant on receipt of four things:

  1. 1A completed tester application on the Department's form.
  2. 2A signed City of Mesa Backflow Assembly Tester Agreement, in which the applicant agrees to follow all city codes and Department procedures.
  3. 3Proof of certification as a tester, which may be a backflow prevention assembly tester certificate.
  4. 4A current gauge accuracy or calibration report for any test equipment the applicant may use.

Once those are in, the city deems the applicant a recognized tester. Staying on the list takes work:

  • Certification (C). A tester must keep current certification. Failing to do so means removal from the list.
  • Calibration (D). Test equipment must be calibrated every year through an agency the Department accepts, and an accuracy report must be submitted each year. A report dated more than one year old is expired, and a tester without a current report on file is removed from the list.
  • Discipline (E), (F). The Department may discipline testers for breaking the tester agreement, the chapter or Department procedures. The code names improper test protocol, a late testing record (more than seven calendar days after the test), fraudulent reporting and other improper practices. Discipline runs from a warning to permanent suspension from testing in the city.
  • Appeal (G). A suspended or removed tester can request a hearing in writing with the Water Resources Director within 15 days of the notice. The hearing is held within 15 days of the request, and the director's decision is final and binding.

What do the key terms mean?

  • Recognized tester. A certified tester the city has approved after the application, agreement, certificate and gauge report.
  • Gauge accuracy report. Proof from an accepted agency that the test gauge works as the manufacturer designed it.
  • Testing record. The report of a test, which the city treats as late if submitted more than seven calendar days after the test.
  • Department. Mesa Water Resources, which runs the backflow program.

Who does this cover?

Owners of buildings with backflow assemblies get the practical benefit, because their annual test under 8-1-11 has to come from a recognized tester. Testers are the ones bound by the calibration, records and discipline rules. Fire sprinkler assemblies follow their own rules on the 8-1-10 page.

Quick check: is this tester and this test acceptable?

SituationAcceptable?Basis
Tester on the city's recognized list, current certification and gauge reportYes8-1-12(A), (B)
Tester with an expired gauge accuracy reportNo, removed from the list8-1-12(D)
Tester whose certification lapsedNo, removed from the list8-1-12(C)
Test record submitted nine days after the testLate, and can lead to discipline8-1-12(E)
Tester suspended for improper protocolCan appeal in writing within 15 days8-1-12(G)
Owner with a certificate but no city recognitionNot enough to test in Mesa8-1-12(A)

What does this look like in real life?

A property manager hiring a tester. The manager asks for proof the tester is recognized by Mesa, not just certified. The test result and the repair deadline both run from a report the city accepts.

A tester whose gauge lapses. The annual accuracy report is dated 13 months ago. Under (D) it is expired, and the tester is removed from the list until a current report is on file.

The edge case. A tester runs a good test but files the report on the tenth day. Under (E) that is a late record, and the Department may discipline the tester even though the assembly passed.

What should you do next?

  1. 1Ask any tester you hire for confirmation that Mesa currently recognizes them.
  2. 2Confirm the calibration report on file is less than a year old.
  3. 3Ask when the test record will be filed, and expect it within seven calendar days.
  4. 4Keep the assembly's annual test schedule and repair deadlines on the calendar.
  5. 5If you are a tester, submit the application, signed agreement, certificate and gauge report together.

What do people get wrong?

  • "Any certified tester will do." The city has to recognize the tester as well.
  • "A gauge report lasts as long as the gauge." It expires after one year.
  • "Only the tester is affected by a late record." The record is what shows the city the assembly was tested, so the owner needs it filed too. Under 8-1-13(A)(a), water service may be terminated when testing records have not been timely provided.
  • "There is no way back after suspension." The code provides a written appeal to the Water Resources Director.

How Do Other Valley Cities Handle It?

WhereWhat appliesSource
GlendaleGlendale requires the customer to test and service backflow devices at least once a year, and the annual testing must be done by an individual certified and approved by the city. The city keeps a list of approved individuals available on request, and the customer keeps test and repair records and sends copies to the city.Glendale City Code 33-94
Verified September 29, 2026
ScottsdaleScottsdale tests yearly on a notice from the city. Records go to the city within 7 days, and only certified, approved testers may install, test, repair or replace an assembly.Scottsdale City Code 49-65
Verified September 29, 2026

This page explains the rule. The official text at the source above governs.