Does a Goodyear restaurant need a grease trap or interceptor? Size, 180-day pumping and records

Verified October 4, 2026
In Short

Yes. Goodyear Ordinance 12A requires every food service establishment to install an appropriately sized grease trap or grease interceptor. Interceptors run 500 to 2,500 gallons, traps are limited to four food-prep fixtures and no dishwasher, and every trap and interceptor is cleaned out completely at least every 180 days unless the director allows otherwise in writing.

Official Source
City of Goodyear: Industrial Pretreatment Program (Water Services)
City of Goodyear Ordinance 12A, Article 12A-3 (Pretreatment of Wastewater); Industrial Pretreatment Program page
“Per City of Goodyear Ordinance 12A, all food service establishments (FSE) in Goodyear are required to install an appropriately sized grease trap or grease interceptor.”
Applies to:
Goodyear restaurants, bars, coffee shops, delis, kiosks, school and hospital kitchens and any other food service establishment, with their owners, tenants and installers; not residential users
Official fee:
Administrative and penalty fees for inspections and compliance tracking, amounts not stated in the article
In force:
Goodyear City Code Chapter 12A, Article 12A-3, enacted by Ord. 14-1290 (3-3-2014) and amended by Ord. 23-1584 (9-25-2023); code current through Ord. 26-1648 (4-27-2026) per the code site
Last verified:
October 4, 2026, against the official page

Goodyear's city page gives the short version: food service means a trap or an interceptor. The code behind it, Chapter 12A, is where the numbers are, including a 180-day cleaning cycle that surprises people who assume the schedule is set by their hauler.

What does Goodyear Ordinance 12A say?

The city's Industrial Pretreatment Program page puts it in one line: "Per City of Goodyear Ordinance 12A, all food service establishments (FSE) in Goodyear are required to install an appropriately sized grease trap or grease interceptor." It adds that the type, size and maintenance of the device depend on a variety of factors. Article 12A-3 supplies those factors:

  • Who can be required. The director may require users, "which includes food preparation facilities," to install grease, lint, sand/oil interceptors, oil/water separators, hair or grease traps as needed for wastewater with excessive fats, oils, grease, lint or sand. Residential users are excepted.
  • Upkeep. Interceptors, separators and traps are inspected, cleaned and repaired regularly by the user at the user's expense, and the user keeps records of all cleaning, repair and maintenance for at least three years, available to the director on request.
  • Size. Sizing uses the drainage fixture unit value. The minimum interceptor is 500 gallons, the maximum 2,500, with at least two chambers. A trap is a minimum of 50 gallons per minute and 100 pounds of capacity.
  • Cleaning cycle. "All grease traps, oil, sand, and grease interceptors shall be pumped out or cleaned out completely at least once every 180 days, or more frequently as required by the City, unless otherwise authorized in writing by the Director."
  • Fees. The city assesses administrative and penalty fees and costs for inspections and compliance tracking.

What do the key terms mean?

  • Food service establishment (FSE). Chapter 12A-1 defines it as any facility that prepares or serves food and discharges kitchen or food preparation wastewater. The list includes bars, delis, kiosks, snack bars, ice cream shops, coffee shops and diners, plus "any establishment that requires a county food service license" and any facility the city decides needs a trap or interceptor because of its operations.
  • Grease trap. A device that separates and retains greases before the wastewater enters the sewer, typically a compact under-the-sink unit near food preparation.
  • Grease interceptor. A structure for removing fats, oils and grease, often a below-ground two or three chamber baffled tank.
  • Appropriately sized. The city page gives no gallon figure. The ordinance sizes devices with the formula in Article 12A-3.

Who does this cover?

Every Goodyear food service establishment, which the definition extends to any establishment that requires a county food service license. It does not cover residential users, who are excepted from the interceptor requirement.

It also does not mean every FSE gets an interceptor. A trap is allowed only when there are four or fewer fixtures used for food preparation, and a facility installing a dishwasher must install an interceptor.

Quick check: trap, interceptor, or neither?

SituationOutcomeWhy
Food prep with four or fewer fixtures, no dishwasherTrap allowed (50 gpm, 100 lb minimum)12A-3 trap rule
Five or more food-prep fixturesInterceptorTraps allowed only at four or fewer
Any dishwasher installedInterceptor"Any facility installing a dishwasher shall install a grease interceptor"
County requires a three-compartment sinkA grease trap shall be installedTrap installation rule
Interceptor calculated at 750 gallons or moreThree chambers, each with a manwayInterceptor construction rule
Interceptor calculates under 500 gallonsStill a minimum 500-gallon, two-chamber concrete container (other materials need the director's approval)Interceptor construction rule
Home kitchenNo interceptorResidential users excepted
Interceptor not cleaned in 180 daysOut of compliance unless the director authorized a different cycle in writingCleaning-cycle rule

What does this look like in real life?

A coffee shop with a three-compartment sink and a prep sink. Two food-prep fixtures and no dishwasher, so a trap qualifies. The county's three-compartment sink requirement is itself a trigger for a trap.

A small cafe adds a dishwasher. The dishwasher forces an interceptor. The sizing arithmetic is the one in the article: total the drainage fixture unit values, multiply by 3 gpm, multiply by 12, and round up to the next size. As an illustration, a kitchen with two 2-inch fixtures (3 units each), one 3-inch fixture (5), two floor drains (2 each) and a 2-inch dishwasher outlet (3, doubled to 6 under one reading of "Double Size") totals 21 units, 63 gpm and 756 gallons before rounding. At 750 gallons or more the interceptor needs three chambers, each with a manway.

The edge case. A contractor orders a traffic-rated lid with wording that says the interceptor belongs to the city. The article says the covers "must not be marked with any wording indicating it is owned by the City of Goodyear."

What should you do next?

  1. 1Count your food-prep fixtures, floor drains and dishwashers using the table in 12A-3, and total the drainage fixture units.
  2. 2Contact Goodyear Development Services about the Industrial Pretreatment Program questionnaire and plan review. The city's pretreatment page tells businesses to contact Development Services (DSD), and its footer lists 623-932-3910.
  3. 3Ask whether your trap or interceptor needs plan review. The first section of Article 12A-3 requires detailed plans for wastewater treatment facilities to be accepted and approved by the city before construction or installation, and the director can require interceptors under the section that follows.
  4. 4Set up the 180-day cleanout cycle, and ask the director in writing if you want a different cycle.
  5. 5Start a record file for every cleaning, repair and maintenance visit, kept for at least three years and ready for the director.

HQ Plumbing & Air repairs and inspects grease interceptors. A separate pumper does the pump-out first.

What do people get wrong?

  • Myth: a trap is fine for any kitchen. It is allowed only with four or fewer food-prep fixtures and no dishwasher.
  • Myth: the cleanout schedule is up to the hauler. The article sets 180 days, or more often if the city requires.
  • Myth: bigger is always allowed. The maximum interceptor is 2,500 gallons.
  • Myth: the city page is the whole rule. It points to Ordinance 12A, where the sizing and cleaning rules live.

Full text and source

The text above comes from the City of Goodyear Industrial Pretreatment Program page and Chapter 12A of the Goodyear City Code, read on 2026-10-04. This page explains them, and the official text governs.

How Do Other Valley Cities Handle It?

WhereWhat appliesSource
MesaMesa uses the same drainage-fixture-unit method and the same 500 to 2,500 gallon range, but its fixture table has no floor drain row, and its interceptor section does not carry Goodyear's 180-day pumping rule.Mesa City Code 8-4-22
Verified October 4, 2026
BuckeyeBuckeye sets a higher floor: unless the director approves otherwise, an interceptor is not smaller than 750 gallons nor larger than 2,500 gallons, and chemicals or bacteria to dissolve grease are specifically prohibited.Buckeye City Code 16-10-2(B)
Verified October 4, 2026
GlendaleGlendale also requires a complete pump-out or clean-out at least once every 180 days, and adds that decanting removed waste back into the trap or interceptor is strictly prohibited.Glendale City Code 33-238
Verified October 4, 2026

This page explains the rule. The official text at the source above governs.