Quick Answer

A whistling, humming or chattering regulator is usually reacting to fast-moving water: an undersized valve or pipe, a worn seat washer or loose seal ring, or a pressure drop bigger than 3 to 1. Manufacturers suggest cleaning or repairing the valve, or adding a second valve in series. Banging is water hammer, a different problem.

What the noise usually is

Zurn Wilkins, which makes the Wilkins line of pressure reducing valves (PRVs), has a troubleshooting entry for exactly this: "Valve appears to be noisy; chatters, hums, whistles." Its instructions list three causes, and each has its own fix:

  1. 1High velocity of flow in the pipelines, causing vibration. The fix is to check whether the valve or the pipes are undersized.
  2. 2A worn seat washer or a loosely installed seal ring. The fix is to clean the valve, and repair it with a repair kit if the seal ring is damaged.
  3. 3A pressure reduction greater than 3 to 1. The fix is to try a higher setting or add a second valve in series.

The manual's own preface explains the first one: "high velocity tends to cause whistling and humming." Water squeezing through a small passage at speed is like air through a narrow gap. It makes a sound, and the sound tends to be high-pitched.

So the noise points at one of three things: the flow, the parts, or the pressure drop. Sorting out which one is the job.

Is the pressure drop too big?

Manufacturers treat a big drop as a reason for noise and early wear. Zurn's specification sheet says "Multiple installations are recommend for wide demand variations or where the desired pressure reduction is more than 3 to 1 (i.e.: 150 psi inlet reduced to 50 psi outlet)." Its Model 600XL instructions repeat the idea with different numbers: "Where the desired pressure reduction is more than a 3 to 1 ratio (i.e. 225psi to 75psi), or inlet pressure is above 150 PSI multiple regulators in series are recommended to be installed to prolong valve life."

FEBCO, a Watts brand, says the same about staging. Its installation sheet says series installations "are recommended where very high supply pressure must be reduced to a very low downstream pressure," and "Reducing the pressure in stages eliminates whistling and noise."

Do the math on your own setup. Phoenix says "An acceptable pressure range within the City of Phoenix is between 40 and 100 psi." If your street pressure is 100 psi and the valve is set to 50, that's a 2 to 1 reduction, and the ratio probably isn't your problem. If street pressure is high and the valve is set low, the ratio gets steeper. Getting your supply pressure and your set pressure from a gauge is how you find out. Our page on why water pressure is different in different parts of Phoenix explains the range you can expect.

Zurn's quick test for a big ratio is to "increase set pressure temporarily to see if noise goes away." Do this carefully and only with a gauge. The plumbing code caps the pressure in the building's piping at 80 psi static, and manufacturers say not to bottom out the adjustment bolt. If the noise stops at a slightly higher setting, that points at the ratio, and a second valve in series is the manufacturer's fix. It's a job for a plumber, because it means changing piping. Our page on which way to turn a pressure regulator shows the safe way to adjust and verify.

Worn parts, debris and sizing

The second cause is inside the valve. A pressure reducing valve has a seat, a disc or seal ring, and a stem, and the water passes between them. That is why Zurn lists a worn seat washer or a loosely installed seal ring as a cause of noise.

Zurn's instruction is to follow its maintenance and cleaning steps and, "If a deep channel appears on seal ring face, repair the valve with a Wilkins repair kit." Its notice also says "Periodic inspection and maintenance is required of all plumbing system components, at least once per year or more as service conditions warrant." Few homeowners do that, so a valve that's been in the wall for years without a look is a fair suspect.

Debris matters as well. Zurn notes that for pressure that builds up past the setting, the cause can be "Debris on seating face of seal ring," and the first step is to "Flush the reducing valve by opening multiple fixture outlets wide open." If the noise started right after work on the water lines, sediment is worth considering. Zurn's guide also lists a screen clogged with debris as a cause of unsteady flow.

Zurn also warns that "Corrosive water conditions, and/or unauthorized adjustments or repair could render the product ineffective for the service intended."

### Undersized valve or pipe

The third cause is a mismatch between the valve or pipe and how much water your house calls for. Zurn's guide says: "The valve or the pipelines could be undersized. Pipes and valves being undersized would accentuate this condition." And it adds a sizing rule: "When actual water demands are unknown, the valve size should be no less than the existing pipe size."

It can show up when a house adds fixtures, a bigger irrigation zone or a second water heater on a line that was sized for less. The noise is loudest at high flow, when several fixtures run at once. If it's quiet with one faucet open and loud with the shower and washer on together, the flow is the suspect. Zurn's answer is to "Contact a qualified licensed plumber for assistance to determine if the valve size or pipe size should be increased."

Is it really the regulator?

The regulator is often blamed for noises it doesn't make. Two other sounds get mixed up with it.

Banging. A single loud bang when a faucet or appliance valve shuts is water hammer. Watts explains that "water hammer is very simply the noise generated by the shocks of high-speed water flowing in a pipe when a fixture is suddenly closed." The plumbing code says a "water-hammer arrestor shall be installed where quick-closing valves are utilized." Our page on banging pipes covers that. High pressure makes hammer worse, so a failing regulator can contribute, and the signs a pressure reducing valve is going bad explain how to tell.

Noise in a fixture. A hum or whistle at one faucet or one appliance often starts there, not at the regulator, and it travels through the pipes. If only one fixture makes the sound, see low water pressure at one fixture for aerator and cartridge causes.

Two quick observations help sort it out. Note when the sound happens: constantly, only at high flow, or only when a single fixture runs. And put a hand on the valve body while the noise is happening. If the vibration is strongest there, the regulator is the source.

What to do about it

Start with a pressure gauge on a hose bib. If pressure is high, or the reading swings while the noise happens, the valve has a problem beyond noise. Then work through the causes in order: clean or repair the valve if it's worn, check the sizing if the noise comes at high flow, and add a second valve if the drop is steep.

If you'd rather have someone else sort it, HQ Plumbing & Air can test your pressure and repair or replace a PRV. Licensed and insured, free estimates, price up front before work starts, and 24/7 availability.

Here's the takeaway. Noise means velocity, worn parts or a steep drop. Find which, and the valve usually goes quiet.

Related Questions

pressure regulatorPRV noisewhistlingwater pressure

Need A Phoenix Plumber?